Source code for nirfmxcdma2k.chp_configuration

"""Provides methods to configure the Chp measurement."""

import functools

import nirfmxcdma2k.attributes as attributes
import nirfmxcdma2k.enums as enums
import nirfmxcdma2k.errors as errors
import nirfmxcdma2k.internal._helper as _helper


def _raise_if_disposed(f):
    """From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""

    @functools.wraps(f)
    def aux(*xs, **kws):
        meas_obj = xs[0]  # parameter 0 is 'self' which is the measurement object
        if meas_obj._signal_obj.is_disposed:
            raise Exception("Cannot access a disposed Cdma2k signal configuration")
        return f(*xs, **kws)

    return aux


[docs] class ChpConfiguration(object): """Provides methods to configure the Chp measurement.""" def __init__(self, signal_obj): """Provides methods to configure the Chp measurement.""" self._signal_obj = signal_obj self._session_function_lock = signal_obj._session_function_lock self._interpreter = signal_obj._interpreter
[docs] @_raise_if_disposed def get_measurement_enabled(self, selector_string): r"""Gets whether to enable the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (bool): Specifies whether to enable the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_ENABLED.value ) attr_val = bool(attr_val) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_measurement_enabled(self, selector_string, value): r"""Sets whether to enable the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. value (bool): Specifies whether to enable the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_MEASUREMENT_ENABLED.value, int(value), ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_integration_bandwidth(self, selector_string): r"""Gets the CHP carrier integration bandwidth. This value is expressed in Hz. You do not need to use a selector string to read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Returns the CHP carrier integration bandwidth. This value is expressed in Hz. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_INTEGRATION_BANDWIDTH.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def get_rbw_filter_auto_bandwidth(self, selector_string): r"""Gets whether the measurement computes the RBW. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+-------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================================+ | False (0) | The measurement uses the RBW that you specify in the CHP RBW attribute. | +--------------+-------------------------------------------------------------------------+ | True (1) | The measurement computes the RBW. | +--------------+-------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpRbwAutoBandwidth): Specifies whether the measurement computes the RBW. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH.value ) attr_val = enums.ChpRbwAutoBandwidth(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_rbw_filter_auto_bandwidth(self, selector_string, value): r"""Sets whether the measurement computes the RBW. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+-------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================================+ | False (0) | The measurement uses the RBW that you specify in the CHP RBW attribute. | +--------------+-------------------------------------------------------------------------+ | True (1) | The measurement computes the RBW. | +--------------+-------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpRbwAutoBandwidth, int): Specifies whether the measurement computes the RBW. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpRbwAutoBandwidth else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_rbw_filter_bandwidth(self, selector_string): r"""Gets the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 10 kHz. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Specifies the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is expressed in Hz. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_rbw_filter_bandwidth(self, selector_string, value): r"""Sets the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is expressed in Hz. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 10 kHz. Args: selector_string (string): Pass an empty string. value (float): Specifies the bandwidth of the RBW filter used to sweep the acquired signal when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_RBW_FILTER_AUTO_BANDWIDTH` attribute to **False**. This value is expressed in Hz. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_BANDWIDTH.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_rbw_filter_type(self, selector_string): r"""Gets the shape of the digital RBW filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **Gaussian**. +---------------+----------------------------------------------------+ | Name (Value) | Description | +===============+====================================================+ | FFT Based (0) | No RBW filtering is performed. | +---------------+----------------------------------------------------+ | Gaussian (1) | An RBW filter with a Gaussian response is applied. | +---------------+----------------------------------------------------+ | Flat (2) | An RBW filter with a flat response is applied. | +---------------+----------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpRbwFilterType): Specifies the shape of the digital RBW filter. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_TYPE.value ) attr_val = enums.ChpRbwFilterType(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_rbw_filter_type(self, selector_string, value): r"""Sets the shape of the digital RBW filter. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **Gaussian**. +---------------+----------------------------------------------------+ | Name (Value) | Description | +===============+====================================================+ | FFT Based (0) | No RBW filtering is performed. | +---------------+----------------------------------------------------+ | Gaussian (1) | An RBW filter with a Gaussian response is applied. | +---------------+----------------------------------------------------+ | Flat (2) | An RBW filter with a flat response is applied. | +---------------+----------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpRbwFilterType, int): Specifies the shape of the digital RBW filter. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpRbwFilterType else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_RBW_FILTER_TYPE.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_sweep_time_auto(self, selector_string): r"""Gets whether the measurement computes the sweep time. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+---------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=======================================================================================+ | False (0) | The measurement uses the sweep time that you specify in the CHP Sweep Time attribute. | +--------------+---------------------------------------------------------------------------------------+ | True (1) | The measurement uses the default sweep time of 0.001667 seconds. | +--------------+---------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpSweepTimeAuto): Specifies whether the measurement computes the sweep time. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_AUTO.value ) attr_val = enums.ChpSweepTimeAuto(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_sweep_time_auto(self, selector_string, value): r"""Sets whether the measurement computes the sweep time. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **True**. +--------------+---------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=======================================================================================+ | False (0) | The measurement uses the sweep time that you specify in the CHP Sweep Time attribute. | +--------------+---------------------------------------------------------------------------------------+ | True (1) | The measurement uses the default sweep time of 0.001667 seconds. | +--------------+---------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpSweepTimeAuto, int): Specifies whether the measurement computes the sweep time. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpSweepTimeAuto else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_AUTO.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_sweep_time_interval(self, selector_string): r"""Gets the sweep time when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 0.001667 seconds. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (float): Specifies the sweep time when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. This value is expressed in seconds. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_INTERVAL.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_sweep_time_interval(self, selector_string, value): r"""Sets the sweep time when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. This value is expressed in seconds. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 0.001667 seconds. Args: selector_string (string): Pass an empty string. value (float): Specifies the sweep time when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_SWEEP_TIME_AUTO` attribute to **False**. This value is expressed in seconds. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_f64( updated_selector_string, attributes.AttributeID.CHP_SWEEP_TIME_INTERVAL.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_enabled(self, selector_string): r"""Gets whether to enable averaging for the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **False**. +--------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+==========================================================================================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ | True (1) | The CHP measurement uses the CHP Averaging Count attribute as the number of acquisitions over which the CHP measurement | | | is averaged. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpAveragingEnabled): Specifies whether to enable averaging for the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_ENABLED.value ) attr_val = enums.ChpAveragingEnabled(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_enabled(self, selector_string, value): r"""Sets whether to enable averaging for the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **False**. +--------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+==========================================================================================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ | True (1) | The CHP measurement uses the CHP Averaging Count attribute as the number of acquisitions over which the CHP measurement | | | is averaged. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpAveragingEnabled, int): Specifies whether to enable averaging for the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpAveragingEnabled else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_ENABLED.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_count(self, selector_string): r"""Gets the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 10. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_COUNT.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_count(self, selector_string, value): r"""Sets the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 10. Args: selector_string (string): Pass an empty string. value (int): Specifies the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHP_AVERAGING_ENABLED` attribute to **True**. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_COUNT.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_type(self, selector_string): r"""Gets the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **RMS**. +--------------+-------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=============================================================================================================+ | RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Log (1) | The power spectrum is averaged on a logarithmic scale. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Scalar (2) | The square root of the power spectrum is averaged. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Min (4) | The lowest power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ChpAveragingType): Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_TYPE.value ) attr_val = enums.ChpAveragingType(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_type(self, selector_string, value): r"""Sets the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is **RMS**. +--------------+-------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +==============+=============================================================================================================+ | RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Log (1) | The power spectrum is averaged on a logarithmic scale. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Scalar (2) | The square root of the power spectrum is averaged. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Min (4) | The lowest power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ChpAveragingType, int): Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ChpAveragingType else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_AVERAGING_TYPE.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_all_traces_enabled(self, selector_string): r"""Gets whether to enable the traces to be stored and retrieved after performing the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (bool): Specifies whether to enable the traces to be stored and retrieved after performing the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_ALL_TRACES_ENABLED.value ) attr_val = bool(attr_val) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_all_traces_enabled(self, selector_string, value): r"""Sets whether to enable the traces to be stored and retrieved after performing the CHP measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. value (bool): Specifies whether to enable the traces to be stored and retrieved after performing the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_ALL_TRACES_ENABLED.value, int(value), ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_number_of_analysis_threads(self, selector_string): r"""Gets the maximum number of threads used for parallelism for the CHP measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 1. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the maximum number of threads used for parallelism for the CHP measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_ANALYSIS_THREADS.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_number_of_analysis_threads(self, selector_string, value): r"""Sets the maximum number of threads used for parallelism for the CHP measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for information about the string syntax for named signals. The default value is 1. Args: selector_string (string): Pass an empty string. value (int): Specifies the maximum number of threads used for parallelism for the CHP measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.CHP_NUMBER_OF_ANALYSIS_THREADS.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_averaging( self, selector_string, averaging_enabled, averaging_count, averaging_type ): r"""Configures averaging for the CHP measurement. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. averaging_enabled (enums.ChpAveragingEnabled, int): This parameter specifies whether to enable averaging for the measurement. The default value is **False**. +--------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (value) | Description | +==============+==========================================================================================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ | True (1) | The CHP measurement uses the Averaging Count parameter to calculate the number of acquisitions over which the CHP | | | measurement is averaged. | +--------------+--------------------------------------------------------------------------------------------------------------------------+ averaging_count (int): This parameter specifies the number of acquisitions used for averaging when you set the **Averaging Enabled** parameter to **True**. The default value is 10. averaging_type (enums.ChpAveragingType, int): This parameter specifies the averaging type for averaging multiple spectrum acquisitions. RFmx uses the averaged spectrum for the measurement. The default value is **RMS**. +--------------+-------------------------------------------------------------------------------------------------------------+ | Name (value) | Description | +==============+=============================================================================================================+ | RMS (0) | The power spectrum is linearly averaged. RMS averaging reduces signal fluctuations but not the noise floor. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Log (1) | The power spectrum is averaged in a logarithmic scale. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Scalar (2) | The square root of the power spectrum is averaged. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Max (3) | The peak power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ | Min (4) | The least power in the spectrum at each frequency bin is retained from one acquisition to the next. | +--------------+-------------------------------------------------------------------------------------------------------------+ Refer to the *Averaging* section of the *Spectrum* topic for more information about averaging types. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") averaging_enabled = ( averaging_enabled.value if type(averaging_enabled) is enums.ChpAveragingEnabled else averaging_enabled ) averaging_type = ( averaging_type.value if type(averaging_type) is enums.ChpAveragingType else averaging_type ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.chp_configure_averaging( updated_selector_string, averaging_enabled, averaging_count, averaging_type ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_rbw_filter(self, selector_string, rbw_auto, rbw, rbw_filter_type): r"""Configures the RBW filter. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. rbw_auto (enums.ChpRbwAutoBandwidth, int): This parameter specifies whether the measurement computes the RBW. The default value is **True**. Refer to the *RBW and Sweep Time* section in the *CHP* topic for more information about RBW and sweep time. +--------------+---------------------------------------------------------------------+ | Name (value) | Description | +==============+=====================================================================+ | False (0) | The measurement uses the RBW that you specify in the RBW parameter. | +--------------+---------------------------------------------------------------------+ | True (1) | The measurement computes the RBW. | +--------------+---------------------------------------------------------------------+ rbw (float): This parameter specifies the bandwidth of the RBW filter used to sweep the acquired signal if you set the **RBW Auto** parameter to **False**. This value is expressed in Hz. rbw_filter_type (enums.ChpRbwFilterType, int): This parameter specifies the shape of the digital RBW filter. The default value is **Gaussian**. +---------------+----------------------------------------------------+ | Name (value) | Description | +===============+====================================================+ | FFT Based (0) | No RBW filtering is performed. | +---------------+----------------------------------------------------+ | Gaussian (1) | An RBW filter with a Gaussian response is applied. | +---------------+----------------------------------------------------+ | Flat (2) | An RBW filter with a flat response is applied. | +---------------+----------------------------------------------------+ Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") rbw_auto = rbw_auto.value if type(rbw_auto) is enums.ChpRbwAutoBandwidth else rbw_auto rbw_filter_type = ( rbw_filter_type.value if type(rbw_filter_type) is enums.ChpRbwFilterType else rbw_filter_type ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.chp_configure_rbw_filter( updated_selector_string, rbw_auto, rbw, rbw_filter_type ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_sweep_time(self, selector_string, sweep_time_auto, sweep_time_interval): r"""Configures the sweep time. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. sweep_time_auto (enums.ChpSweepTimeAuto, int): This parameter specifies whether the measurement computes the sweep time. The default value is **True** . +--------------+-----------------------------------------------------------------------------------------------+ | Name (value) | Description | +==============+===============================================================================================+ | False (0) | The measurement uses the sweep time that you specify using the Sweep Time Interval parameter. | +--------------+-----------------------------------------------------------------------------------------------+ | True (1) | The measurement uses the default sweep time of 0.001667 seconds. | +--------------+-----------------------------------------------------------------------------------------------+ Refer to the *RBW and Sweep Time* section in the *CHP* topic for more information about RBW and sweep time. sweep_time_interval (float): This parameter specifies the sweep time if you set the **Sweep Time Auto** parameter to **False**. This value is expressed in seconds. The default value is 0.00167 seconds. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") sweep_time_auto = ( sweep_time_auto.value if type(sweep_time_auto) is enums.ChpSweepTimeAuto else sweep_time_auto ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.chp_configure_sweep_time( updated_selector_string, sweep_time_auto, sweep_time_interval ) finally: self._session_function_lock.exit_read_lock() return error_code