"""Defines a root class which is used to identify and control Cdma2k signal configuration."""
import functools
import math
import nirfmxcdma2k.acp as acp
import nirfmxcdma2k.attributes as attributes
import nirfmxcdma2k.cda as cda
import nirfmxcdma2k.chp as chp
import nirfmxcdma2k.enums as enums
import nirfmxcdma2k.errors as errors
import nirfmxcdma2k.internal._helper as _helper
import nirfmxcdma2k.modacc as modacc
import nirfmxcdma2k.obw as obw
import nirfmxcdma2k.qevm as qevm
import nirfmxcdma2k.sem as sem
import nirfmxcdma2k.slotphase as slotphase
import nirfmxcdma2k.slotpower as slotpower
import nirfmxinstr
from nirfmxcdma2k.internal._helper import SignalConfiguration
class _Cdma2kSignalConfiguration:
"""Contains static methods to create and delete Cdma2k signal."""
@staticmethod
def get_cdma2k_signal_configuration(instr_session, signal_name="", cloning=False):
updated_signal_name = signal_name
if signal_name:
updated_signal_name = _helper.validate_and_remove_signal_qualifier(
signal_name, "signal_name"
)
_helper.validate_signal_not_empty(updated_signal_name, "signal_name")
return _Cdma2kSignalConfiguration.init(instr_session, updated_signal_name, cloning) # type: ignore
@staticmethod
def init(instr_session, signal_name, cloning):
with instr_session._signal_lock:
if signal_name.lower() == Cdma2k._default_signal_name_user_visible.lower():
signal_name = Cdma2k._default_signal_name
existing_signal = instr_session._signal_manager.find_signal_configuration(
Cdma2k._signal_configuration_type, signal_name
)
if existing_signal is None:
signal_configuration = Cdma2k(instr_session, signal_name, cloning) # type: ignore
instr_session._signal_manager.add_signal_configuration(signal_configuration)
else:
signal_configuration = existing_signal
# Checking if signal exists in C layer
if signal_configuration._interpreter.check_if_current_signal_exists() is False:
if not signal_configuration.signal_configuration_name.lower():
instr_session._interpreter.create_default_signal_configuration(
Cdma2k._default_signal_name_user_visible,
int(math.log(nirfmxinstr.Personalities.CDMA2K.value, 2.0)) + 1,
)
else:
signal_configuration._interpreter.create_signal_configuration(signal_name)
return signal_configuration
@staticmethod
def remove_signal_configuration(instr_session, signal_configuration):
with instr_session._signal_lock:
instr_session._signal_manager.remove_signal_configuration(signal_configuration)
def _raise_if_disposed(f):
"""From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""
@functools.wraps(f)
def aux(*xs, **kws):
signal = xs[0] # parameter 0 is 'self' which is the signal object
if signal.is_disposed:
raise Exception("Cannot access a disposed Cdma2k signal configuration")
return f(*xs, **kws)
return aux
class _Cdma2kBase(SignalConfiguration):
"""Defines a base class for Cdma2k."""
_default_signal_name = ""
_default_signal_name_user_visible = "default@CDMA2k"
_signal_configuration_type = "<'nirfmxcdma2k.cdma2k.Cdma2k'>"
def __init__(self, session, signal_name="", cloning=False):
self.is_disposed = False
self._rfmxinstrsession = session
self._rfmxinstrsession_interpreter = session._interpreter
self.signal_configuration_name = signal_name
self.signal_configuration_type = type(self) # type: ignore
self._signal_configuration_mode = "Signal"
if session._is_remote_session:
import nirfmxcdma2k.internal._grpc_stub_interpreter as _grpc_stub_interpreter
interpreter = _grpc_stub_interpreter.GrpcStubInterpreter(session._grpc_options, session, self) # type: ignore
else:
from nirfmxcdma2k.internal._library_interpreter import LibraryInterpreter
interpreter = LibraryInterpreter("windows-1251", session, self) # type: ignore
self._interpreter = interpreter
self._interpreter.set_session_handle(self._rfmxinstrsession_interpreter._vi) # type: ignore
self._session_function_lock = _helper.SessionFunctionLock()
# Measurements object
self.acp = acp.Acp(self) # type: ignore
self.chp = chp.Chp(self) # type: ignore
self.modacc = modacc.ModAcc(self) # type: ignore
self.obw = obw.Obw(self) # type: ignore
self.sem = sem.Sem(self) # type: ignore
self.qevm = qevm.Qevm(self) # type: ignore
self.cda = cda.Cda(self) # type: ignore
self.slotpower = slotpower.SlotPower(self) # type: ignore
self.slotphase = slotphase.SlotPhase(self) # type: ignore
if not signal_name and not cloning:
signal_exists, personality, _ = (
self._rfmxinstrsession_interpreter.check_if_signal_exists(
self._default_signal_name_user_visible
)
)
if not (signal_exists and personality.value == nirfmxinstr.Personalities.CDMA2K.value):
self._rfmxinstrsession_interpreter.create_default_signal_configuration(
self._default_signal_name_user_visible,
int(math.log(nirfmxinstr.Personalities.CDMA2K.value, 2.0)) + 1,
)
elif signal_name and not cloning:
signal_exists, personality, _ = (
self._rfmxinstrsession_interpreter.check_if_signal_exists(signal_name)
)
if not (signal_exists and personality.value == nirfmxinstr.Personalities.CDMA2K.value):
self._interpreter.create_signal_configuration(signal_name) # type: ignore
def __enter__(self):
"""Enters the context of the Cdma2k signal configuration."""
return self
def __exit__(self, exc_type, exc_value, traceback):
"""Exits the context of the Cdma2k signal configuration."""
self.dispose() # type: ignore
pass
def dispose(self):
r"""Deletes the signal configuration if it is not the default signal configuration
and clears any trace of the current signal configuration, if any.
.. note::
You can call this function safely more than once, even if the signal is already deleted.
"""
if not self.is_disposed:
if self.signal_configuration_name == self._default_signal_name:
self.is_disposed = True
return
else:
_ = self._delete_signal_configuration(True) # type: ignore
self.is_disposed = True
@_raise_if_disposed
def delete_signal_configuration(self):
r"""Deletes the current instance of a signal.
Returns:
error_code:
Returns the status code of this method.
The status code either indicates success or describes a warning condition.
"""
error_code = self._delete_signal_configuration(False) # type: ignore
return error_code
def _delete_signal_configuration(self, ignore_driver_error):
error_code = 0
try:
if not self.is_disposed:
self._session_function_lock.enter_write_lock()
error_code = self._interpreter.delete_signal_configuration(ignore_driver_error) # type: ignore
_Cdma2kSignalConfiguration.remove_signal_configuration(self._rfmxinstrsession, self) # type: ignore
self.is_disposed = True
finally:
self._session_function_lock.exit_write_lock()
return error_code
@_raise_if_disposed
def get_warning(self):
r"""Retrieves and then clears the warning information for the session.
Returns:
Tuple (warning_code, warning_message):
warning_code (int):
Contains the latest warning code.
warning_message (string):
Contains the latest warning description.
"""
try:
self._session_function_lock.enter_read_lock()
warning_code, warning_message = self._interpreter.get_error() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return warning_code, warning_message
@_raise_if_disposed
def get_error_string(self, error_code):
r"""Gets the description of a driver error code.
Args:
error_code (int):
Specifies an error or warning code.
Returns:
string:
Contains the error description.
"""
try:
self._session_function_lock.enter_read_lock()
error_message = self._interpreter.get_error_string(error_code) # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return error_message
@_raise_if_disposed
def reset_attribute(self, selector_string, attribute_id):
r"""Resets the attribute to its default value.
Args:
selector_string (string):
Specifies the selector string for the property being reset.
attribute_id (PropertyId):
Specifies an attribute identifier.
Returns:
int:
Returns the status code of this method.
The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attribute_id = (
attribute_id.value if type(attribute_id) is attributes.AttributeID else attribute_id
)
error_code = self._interpreter.reset_attribute( # type: ignore
updated_selector_string, attribute_id
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_selected_ports(self, selector_string):
r"""Gets the instrument port to be configured to acquire a signal. Use
:py:meth:`nirfmxinstr.session.Session.get_available_ports` method to get the valid port names.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
**Valid values**
+----------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (value) | Description |
+================+==========================================================================================================================+
| PXIe-5830 | if0, if1 |
+----------------+--------------------------------------------------------------------------------------------------------------------------+
| PXIe-5831/5832 | if0, if1, rf<0-1>/port<x>, where 0-1 indicates one (0) or two (1) mmRH-5582 connections and x is the port number on the |
| | mmRH-5582 front panel |
+----------------+--------------------------------------------------------------------------------------------------------------------------+
| Other devices | "" (empty string) |
+----------------+--------------------------------------------------------------------------------------------------------------------------+
**Default values**
+---------------------+-------------------+
| Name (value) | Description |
+=====================+===================+
| PXIe-5830/5831/5832 | if1 |
+---------------------+-------------------+
| Other devices | "" (empty string) |
+---------------------+-------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (string):
Specifies the instrument port to be configured to acquire a signal. Use
:py:meth:`nirfmxinstr.session.Session.get_available_ports` method to get the valid port names.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_string( # type: ignore
updated_selector_string, attributes.AttributeID.SELECTED_PORTS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_selected_ports(self, selector_string, value):
r"""Sets the instrument port to be configured to acquire a signal. Use
:py:meth:`nirfmxinstr.session.Session.get_available_ports` method to get the valid port names.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
**Valid values**
+----------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (value) | Description |
+================+==========================================================================================================================+
| PXIe-5830 | if0, if1 |
+----------------+--------------------------------------------------------------------------------------------------------------------------+
| PXIe-5831/5832 | if0, if1, rf<0-1>/port<x>, where 0-1 indicates one (0) or two (1) mmRH-5582 connections and x is the port number on the |
| | mmRH-5582 front panel |
+----------------+--------------------------------------------------------------------------------------------------------------------------+
| Other devices | "" (empty string) |
+----------------+--------------------------------------------------------------------------------------------------------------------------+
**Default values**
+---------------------+-------------------+
| Name (value) | Description |
+=====================+===================+
| PXIe-5830/5831/5832 | if1 |
+---------------------+-------------------+
| Other devices | "" (empty string) |
+---------------------+-------------------+
Args:
selector_string (string):
Pass an empty string.
value (string):
Specifies the instrument port to be configured to acquire a signal. Use
:py:meth:`nirfmxinstr.session.Session.get_available_ports` method to get the valid port names.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
_helper.validate_not_none(value, "value")
error_code = self._interpreter.set_attribute_string( # type: ignore
updated_selector_string, attributes.AttributeID.SELECTED_PORTS.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_center_frequency(self, selector_string):
r"""Gets the carrier frequency of the RF signal to acquire. The signal analyzer tunes to this frequency. This value is
expressed in Hz.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the carrier frequency of the RF signal to acquire. The signal analyzer tunes to this frequency. This value is
expressed in Hz.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.CENTER_FREQUENCY.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_center_frequency(self, selector_string, value):
r"""Sets the carrier frequency of the RF signal to acquire. The signal analyzer tunes to this frequency. This value is
expressed in Hz.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the carrier frequency of the RF signal to acquire. The signal analyzer tunes to this frequency. This value is
expressed in Hz.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.CENTER_FREQUENCY.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_reference_level(self, selector_string):
r"""Gets the reference level, which represents the maximum expected power of the RF input signal. This value is
expressed in dBm for RF devices and V\ :sub:`pk-pk`\ for baseband devices.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the reference level, which represents the maximum expected power of the RF input signal. This value is
expressed in dBm for RF devices and V\ :sub:`pk-pk`\ for baseband devices.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.REFERENCE_LEVEL.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_reference_level(self, selector_string, value):
r"""Sets the reference level, which represents the maximum expected power of the RF input signal. This value is
expressed in dBm for RF devices and V\ :sub:`pk-pk`\ for baseband devices.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the reference level, which represents the maximum expected power of the RF input signal. This value is
expressed in dBm for RF devices and V\ :sub:`pk-pk`\ for baseband devices.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.REFERENCE_LEVEL.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_external_attenuation(self, selector_string):
r"""Gets the attenuation of a switch or cable connected to the RF IN connector of the signal analyzer. This value is
expressed in dB. For more information about attenuation, refer to the RF Attenuation and Signal Levels topic for your
device in the *NI RF Vector Signal Analyzers Help*.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0 dB.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the attenuation of a switch or cable connected to the RF IN connector of the signal analyzer. This value is
expressed in dB. For more information about attenuation, refer to the RF Attenuation and Signal Levels topic for your
device in the *NI RF Vector Signal Analyzers Help*.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.EXTERNAL_ATTENUATION.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_external_attenuation(self, selector_string, value):
r"""Sets the attenuation of a switch or cable connected to the RF IN connector of the signal analyzer. This value is
expressed in dB. For more information about attenuation, refer to the RF Attenuation and Signal Levels topic for your
device in the *NI RF Vector Signal Analyzers Help*.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0 dB.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the attenuation of a switch or cable connected to the RF IN connector of the signal analyzer. This value is
expressed in dB. For more information about attenuation, refer to the RF Attenuation and Signal Levels topic for your
device in the *NI RF Vector Signal Analyzers Help*.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.EXTERNAL_ATTENUATION.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_reference_level_headroom(self, selector_string):
r"""Gets the margin RFmx adds to the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.REFERENCE_LEVEL` attribute. The
margin avoids clipping and overflow warnings if the input signal exceeds the configured reference level.
RFmx configures the input gain to avoid clipping and associated overflow warnings provided the instantaneous
power of the input signal remains within the Reference Level plus the Reference Level Headroom. If you know the input
power of the signal precisely or previously included the margin in the Reference Level, you could improve the
signal-to-noise ratio by reducing the Reference Level Headroom.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
**Supported devices**: PXIe-5668R, PXIe-5830/5831/5832/5840/5841/5842/5860.
**Default values**
+------------------------------------+-------------+
| Name (value) | Description |
+====================================+=============+
| PXIe-5668 | 6 dB |
+------------------------------------+-------------+
| PXIe-5830/5831/5832/5841/5842/5860 | 1 dB |
+------------------------------------+-------------+
| PXIe-5840 | 0 dB |
+------------------------------------+-------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the margin RFmx adds to the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.REFERENCE_LEVEL` attribute. The
margin avoids clipping and overflow warnings if the input signal exceeds the configured reference level.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.REFERENCE_LEVEL_HEADROOM.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_reference_level_headroom(self, selector_string, value):
r"""Sets the margin RFmx adds to the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.REFERENCE_LEVEL` attribute. The
margin avoids clipping and overflow warnings if the input signal exceeds the configured reference level.
RFmx configures the input gain to avoid clipping and associated overflow warnings provided the instantaneous
power of the input signal remains within the Reference Level plus the Reference Level Headroom. If you know the input
power of the signal precisely or previously included the margin in the Reference Level, you could improve the
signal-to-noise ratio by reducing the Reference Level Headroom.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
**Supported devices**: PXIe-5668R, PXIe-5830/5831/5832/5840/5841/5842/5860.
**Default values**
+------------------------------------+-------------+
| Name (value) | Description |
+====================================+=============+
| PXIe-5668 | 6 dB |
+------------------------------------+-------------+
| PXIe-5830/5831/5832/5841/5842/5860 | 1 dB |
+------------------------------------+-------------+
| PXIe-5840 | 0 dB |
+------------------------------------+-------------+
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the margin RFmx adds to the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.REFERENCE_LEVEL` attribute. The
margin avoids clipping and overflow warnings if the input signal exceeds the configured reference level.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string,
attributes.AttributeID.REFERENCE_LEVEL_HEADROOM.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_trigger_type(self, selector_string):
r"""Gets the trigger type.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **None**.
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+===================+==========================================================================================================================+
| None (0) | No Reference Trigger is configured. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| Digital Edge (1) | The Reference Trigger is not asserted until a digital edge is detected. The source of the digital edge is specified |
| | using the Digital Edge Source attribute. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| IQ Power Edge (2) | The Reference Trigger is asserted when the signal changes past the level specified by the slope (rising or falling), |
| | which is configured using the IQ Power Edge Source attribute. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| Software (3) | The Reference Trigger is not asserted until a software trigger occurs. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.TriggerType):
Specifies the trigger type.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.TRIGGER_TYPE.value
)
attr_val = enums.TriggerType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_trigger_type(self, selector_string, value):
r"""Sets the trigger type.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **None**.
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+===================+==========================================================================================================================+
| None (0) | No Reference Trigger is configured. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| Digital Edge (1) | The Reference Trigger is not asserted until a digital edge is detected. The source of the digital edge is specified |
| | using the Digital Edge Source attribute. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| IQ Power Edge (2) | The Reference Trigger is asserted when the signal changes past the level specified by the slope (rising or falling), |
| | which is configured using the IQ Power Edge Source attribute. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
| Software (3) | The Reference Trigger is not asserted until a software trigger occurs. |
+-------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.TriggerType, int):
Specifies the trigger type.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.TriggerType else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.TRIGGER_TYPE.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_digital_edge_trigger_source(self, selector_string):
r"""Gets the source terminal for the digital edge trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (string):
Specifies the source terminal for the digital edge trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_string( # type: ignore
updated_selector_string, attributes.AttributeID.DIGITAL_EDGE_TRIGGER_SOURCE.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_digital_edge_trigger_source(self, selector_string, value):
r"""Sets the source terminal for the digital edge trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
value (string):
Specifies the source terminal for the digital edge trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
_helper.validate_not_none(value, "value")
error_code = self._interpreter.set_attribute_string( # type: ignore
updated_selector_string,
attributes.AttributeID.DIGITAL_EDGE_TRIGGER_SOURCE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_digital_edge_trigger_edge(self, selector_string):
r"""Gets the active edge for the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Rising Edge**.
+------------------+--------------------------------------------------------+
| Name (Value) | Description |
+==================+========================================================+
| Rising Edge (0) | The trigger asserts on the rising edge of the signal. |
+------------------+--------------------------------------------------------+
| Falling Edge (1) | The trigger asserts on the falling edge of the signal. |
+------------------+--------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.DigitalEdgeTriggerEdge):
Specifies the active edge for the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.DIGITAL_EDGE_TRIGGER_EDGE.value
)
attr_val = enums.DigitalEdgeTriggerEdge(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_digital_edge_trigger_edge(self, selector_string, value):
r"""Sets the active edge for the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Rising Edge**.
+------------------+--------------------------------------------------------+
| Name (Value) | Description |
+==================+========================================================+
| Rising Edge (0) | The trigger asserts on the rising edge of the signal. |
+------------------+--------------------------------------------------------+
| Falling Edge (1) | The trigger asserts on the falling edge of the signal. |
+------------------+--------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.DigitalEdgeTriggerEdge, int):
Specifies the active edge for the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **Digital Edge**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.DigitalEdgeTriggerEdge else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.DIGITAL_EDGE_TRIGGER_EDGE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_iq_power_edge_trigger_source(self, selector_string):
r"""Gets the channel from which the device monitors the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (string):
Specifies the channel from which the device monitors the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_string( # type: ignore
updated_selector_string, attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_SOURCE.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_iq_power_edge_trigger_source(self, selector_string, value):
r"""Sets the channel from which the device monitors the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
value (string):
Specifies the channel from which the device monitors the trigger. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
_helper.validate_not_none(value, "value")
error_code = self._interpreter.set_attribute_string( # type: ignore
updated_selector_string,
attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_SOURCE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_iq_power_edge_trigger_level(self, selector_string):
r"""Gets the power level at which the device triggers. This value is expressed in dB when the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE` attribute is set to **Relative** and
in dBm when the IQ Power Edge Level Type attribute is set to **Absolute**. The device asserts the trigger when the
signal exceeds the level specified by the value of this attribute, taking into consideration the specified slope. This
attribute is used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ
Power Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the power level at which the device triggers. This value is expressed in dB when the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE` attribute is set to **Relative** and
in dBm when the IQ Power Edge Level Type attribute is set to **Absolute**. The device asserts the trigger when the
signal exceeds the level specified by the value of this attribute, taking into consideration the specified slope. This
attribute is used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ
Power Edge**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_iq_power_edge_trigger_level(self, selector_string, value):
r"""Sets the power level at which the device triggers. This value is expressed in dB when the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE` attribute is set to **Relative** and
in dBm when the IQ Power Edge Level Type attribute is set to **Absolute**. The device asserts the trigger when the
signal exceeds the level specified by the value of this attribute, taking into consideration the specified slope. This
attribute is used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ
Power Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the power level at which the device triggers. This value is expressed in dB when the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE` attribute is set to **Relative** and
in dBm when the IQ Power Edge Level Type attribute is set to **Absolute**. The device asserts the trigger when the
signal exceeds the level specified by the value of this attribute, taking into consideration the specified slope. This
attribute is used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ
Power Edge**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string,
attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_iq_power_edge_trigger_level_type(self, selector_string):
r"""Gets the reference for the IQ Power Edge Level Type attribute. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Relative**.
+--------------+----------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==============================================================================================+
| Relative (0) | The IQ Power Edge Level attribute is relative to the value of the Reference Level attribute. |
+--------------+----------------------------------------------------------------------------------------------+
| Absolute (1) | The IQ Power Edge Level attribute specifies the absolute power. |
+--------------+----------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.IQPowerEdgeTriggerLevelType):
Specifies the reference for the IQ Power Edge Level Type attribute. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE.value,
)
attr_val = enums.IQPowerEdgeTriggerLevelType(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_iq_power_edge_trigger_level_type(self, selector_string, value):
r"""Sets the reference for the IQ Power Edge Level Type attribute. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Relative**.
+--------------+----------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==============================================================================================+
| Relative (0) | The IQ Power Edge Level attribute is relative to the value of the Reference Level attribute. |
+--------------+----------------------------------------------------------------------------------------------+
| Absolute (1) | The IQ Power Edge Level attribute specifies the absolute power. |
+--------------+----------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.IQPowerEdgeTriggerLevelType, int):
Specifies the reference for the IQ Power Edge Level Type attribute. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power Edge**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.IQPowerEdgeTriggerLevelType else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_iq_power_edge_trigger_slope(self, selector_string):
r"""Gets whether the device asserts the trigger when the signal power is rising or when it is falling. The device
asserts the trigger when the signal power exceeds the specified level with the slope you specify. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power
Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Rising Slope**.
+-------------------+-------------------------------------------------------+
| Name (Value) | Description |
+===================+=======================================================+
| Rising Slope (0) | The trigger asserts when the signal power is rising. |
+-------------------+-------------------------------------------------------+
| Falling Slope (1) | The trigger asserts when the signal power is falling. |
+-------------------+-------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.IQPowerEdgeTriggerSlope):
Specifies whether the device asserts the trigger when the signal power is rising or when it is falling. The device
asserts the trigger when the signal power exceeds the specified level with the slope you specify. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power
Edge**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_SLOPE.value
)
attr_val = enums.IQPowerEdgeTriggerSlope(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_iq_power_edge_trigger_slope(self, selector_string, value):
r"""Sets whether the device asserts the trigger when the signal power is rising or when it is falling. The device
asserts the trigger when the signal power exceeds the specified level with the slope you specify. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power
Edge**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Rising Slope**.
+-------------------+-------------------------------------------------------+
| Name (Value) | Description |
+===================+=======================================================+
| Rising Slope (0) | The trigger asserts when the signal power is rising. |
+-------------------+-------------------------------------------------------+
| Falling Slope (1) | The trigger asserts when the signal power is falling. |
+-------------------+-------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.IQPowerEdgeTriggerSlope, int):
Specifies whether the device asserts the trigger when the signal power is rising or when it is falling. The device
asserts the trigger when the signal power exceeds the specified level with the slope you specify. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.TRIGGER_TYPE` attribute to **IQ Power
Edge**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.IQPowerEdgeTriggerSlope else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_SLOPE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_trigger_delay(self, selector_string):
r"""Gets the trigger delay time. This value is expressed in seconds.
If the delay is negative, the measurement acquires pretrigger samples. If the delay is positive, the
measurement acquires post-trigger samples.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0 seconds.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the trigger delay time. This value is expressed in seconds.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.TRIGGER_DELAY.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_trigger_delay(self, selector_string, value):
r"""Sets the trigger delay time. This value is expressed in seconds.
If the delay is negative, the measurement acquires pretrigger samples. If the delay is positive, the
measurement acquires post-trigger samples.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0 seconds.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the trigger delay time. This value is expressed in seconds.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.TRIGGER_DELAY.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_trigger_minimum_quiet_time_mode(self, selector_string):
r"""Gets whether the measurement computes the minimum quiet time used for triggering.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Auto**.
+--------------+---------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=============================================================================================+
| Manual (0) | The minimum quiet time for triggering is the value of the Trigger Min Quiet Time attribute. |
+--------------+---------------------------------------------------------------------------------------------+
| Auto (1) | The measurement computes the minimum quiet time used for triggering. |
+--------------+---------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.TriggerMinimumQuietTimeMode):
Specifies whether the measurement computes the minimum quiet time used for triggering.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.TRIGGER_MINIMUM_QUIET_TIME_MODE.value,
)
attr_val = enums.TriggerMinimumQuietTimeMode(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_trigger_minimum_quiet_time_mode(self, selector_string, value):
r"""Sets whether the measurement computes the minimum quiet time used for triggering.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Auto**.
+--------------+---------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+=============================================================================================+
| Manual (0) | The minimum quiet time for triggering is the value of the Trigger Min Quiet Time attribute. |
+--------------+---------------------------------------------------------------------------------------------+
| Auto (1) | The measurement computes the minimum quiet time used for triggering. |
+--------------+---------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.TriggerMinimumQuietTimeMode, int):
Specifies whether the measurement computes the minimum quiet time used for triggering.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.TriggerMinimumQuietTimeMode else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.TRIGGER_MINIMUM_QUIET_TIME_MODE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_trigger_minimum_quiet_time_duration(self, selector_string):
r"""Gets the time duration for which the signal must be quiet before the signal analyzer arms the I/Q power edge
trigger. This value is expressed in seconds.
If you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_SLOPE` attribute to
**Rising Slope**, the signal is quiet below the trigger level. If you set the IQ Power Edge Slope attribute to
**Falling Slope**, the signal is quiet above the trigger level.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the time duration for which the signal must be quiet before the signal analyzer arms the I/Q power edge
trigger. This value is expressed in seconds.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string,
attributes.AttributeID.TRIGGER_MINIMUM_QUIET_TIME_DURATION.value,
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_trigger_minimum_quiet_time_duration(self, selector_string, value):
r"""Sets the time duration for which the signal must be quiet before the signal analyzer arms the I/Q power edge
trigger. This value is expressed in seconds.
If you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.IQ_POWER_EDGE_TRIGGER_SLOPE` attribute to
**Rising Slope**, the signal is quiet below the trigger level. If you set the IQ Power Edge Slope attribute to
**Falling Slope**, the signal is quiet above the trigger level.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value of this attribute is hardware dependent.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the time duration for which the signal must be quiet before the signal analyzer arms the I/Q power edge
trigger. This value is expressed in seconds.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string,
attributes.AttributeID.TRIGGER_MINIMUM_QUIET_TIME_DURATION.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_link_direction(self, selector_string):
r"""Gets the link direction of the received signal.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Uplink**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| Downlink (0) | CDMA2k measurement uses 3GPP CDMA2k forward link direction also known as downlink direction to measure the received |
| | signal. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Uplink (1) | CDMA2k measurement uses 3GPP CDMA2k reverse link direction also known as uplink direction to measure the received |
| | signal. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.LinkDirection):
Specifies the link direction of the received signal.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.LINK_DIRECTION.value
)
attr_val = enums.LinkDirection(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_link_direction(self, selector_string, value):
r"""Sets the link direction of the received signal.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Uplink**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| Downlink (0) | CDMA2k measurement uses 3GPP CDMA2k forward link direction also known as downlink direction to measure the received |
| | signal. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Uplink (1) | CDMA2k measurement uses 3GPP CDMA2k reverse link direction also known as uplink direction to measure the received |
| | signal. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.LinkDirection, int):
Specifies the link direction of the received signal.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.LinkDirection else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.LINK_DIRECTION.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_band_class(self, selector_string):
r"""Gets the band in which the channel is located as defined in Section: 1.5, Table 1.5- Band Class List, of the 3GPP2
C.S0057-F specification v1.0.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **0**. Valid values are 0 to 12, 14 and 15.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the band in which the channel is located as defined in Section: 1.5, Table 1.5- Band Class List, of the 3GPP2
C.S0057-F specification v1.0.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.BAND_CLASS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_band_class(self, selector_string, value):
r"""Sets the band in which the channel is located as defined in Section: 1.5, Table 1.5- Band Class List, of the 3GPP2
C.S0057-F specification v1.0.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **0**. Valid values are 0 to 12, 14 and 15.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the band in which the channel is located as defined in Section: 1.5, Table 1.5- Band Class List, of the 3GPP2
C.S0057-F specification v1.0.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.BAND_CLASS.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_radio_configuration(self, selector_string):
r"""Gets the radio configuration for the channel.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **RC3**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| RC1 (0) | If Link Direction attribute is set to **Uplink**, Radio configuration 1 includes 64-ary orthogonal modulation, reverse |
| | fundamental channel (R-FCH), and reverse supplemental code channels (R-SCCHs). |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 1 includes binary phase-shift keying (BPSK), |
| | forward fundamental channels (F-FCHs) and forward supplemental channels (F-SCHs). |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC2 (1) | If Link Direction attribute is set to **Uplink**, Radio configuration 2 includes 64-ary orthogonal modulation, R-FCH, |
| | and R-SCCHs. |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 2 includes BPSKs, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC3 (2) | If Link Direction attribute is set to **Uplink**, Radio configuration 3 includes BPSK, R-FCH, and reverse supplemental |
| | channels (R-SCHs). |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 3 includes quadrature phase-shift keying |
| | (QPSK), F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC4 (3) | If Link Direction attribute is set to **Uplink**, Radio configuration 4 includes BPSK, R-FCH, and R-SCHs. |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 4 includes QPSK, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC5 (4) | If Link Direction attribute is set to **Uplink**, Radio configuration 5 is not supported and gives invalid results. |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 5 includes QPSK, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.RadioConfiguration):
Specifies the radio configuration for the channel.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.RADIO_CONFIGURATION.value
)
attr_val = enums.RadioConfiguration(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_radio_configuration(self, selector_string, value):
r"""Sets the radio configuration for the channel.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **RC3**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+==============+==========================================================================================================================+
| RC1 (0) | If Link Direction attribute is set to **Uplink**, Radio configuration 1 includes 64-ary orthogonal modulation, reverse |
| | fundamental channel (R-FCH), and reverse supplemental code channels (R-SCCHs). |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 1 includes binary phase-shift keying (BPSK), |
| | forward fundamental channels (F-FCHs) and forward supplemental channels (F-SCHs). |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC2 (1) | If Link Direction attribute is set to **Uplink**, Radio configuration 2 includes 64-ary orthogonal modulation, R-FCH, |
| | and R-SCCHs. |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 2 includes BPSKs, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC3 (2) | If Link Direction attribute is set to **Uplink**, Radio configuration 3 includes BPSK, R-FCH, and reverse supplemental |
| | channels (R-SCHs). |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 3 includes quadrature phase-shift keying |
| | (QPSK), F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC4 (3) | If Link Direction attribute is set to **Uplink**, Radio configuration 4 includes BPSK, R-FCH, and R-SCHs. |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 4 includes QPSK, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC5 (4) | If Link Direction attribute is set to **Uplink**, Radio configuration 5 is not supported and gives invalid results. |
| | |
| | If Link Direction attribute is set to **Downlink**, Radio Configuration 5 includes QPSK, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.RadioConfiguration, int):
Specifies the radio configuration for the channel.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.RadioConfiguration else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.RADIO_CONFIGURATION.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_channel_configuration_mode(self, selector_string):
r"""Gets whether to detect the channels automatically or to use a specified channel configuration.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Auto Detect**.
+------------------+------------------------------------------------------------------+
| Name (Value) | Description |
+==================+==================================================================+
| Auto Detect (0) | Specifies that the system automatically detects the channels. |
+------------------+------------------------------------------------------------------+
| User Defined (1) | Specifies that the system uses a specific channel configuration. |
+------------------+------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.ChannelConfigurationMode):
Specifies whether to detect the channels automatically or to use a specified channel configuration.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.CHANNEL_CONFIGURATION_MODE.value
)
attr_val = enums.ChannelConfigurationMode(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_channel_configuration_mode(self, selector_string, value):
r"""Sets whether to detect the channels automatically or to use a specified channel configuration.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is **Auto Detect**.
+------------------+------------------------------------------------------------------+
| Name (Value) | Description |
+==================+==================================================================+
| Auto Detect (0) | Specifies that the system automatically detects the channels. |
+------------------+------------------------------------------------------------------+
| User Defined (1) | Specifies that the system uses a specific channel configuration. |
+------------------+------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.ChannelConfigurationMode, int):
Specifies whether to detect the channels automatically or to use a specified channel configuration.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.ChannelConfigurationMode else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.CHANNEL_CONFIGURATION_MODE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_number_of_channels(self, selector_string):
r"""Gets the number of user-defined channels. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the number of user-defined channels. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.NUMBER_OF_CHANNELS.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_number_of_channels(self, selector_string, value):
r"""Sets the number of user-defined channels. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the number of user-defined channels. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.NUMBER_OF_CHANNELS.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_walsh_code_length(self, selector_string):
r"""Gets the Walsh code length of a specific user-defined channel. This value is expressed in chips. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to
**User Defined**.
Use "channel<
<format type="monospace-italic">n</format>
>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to
configure or read this attribute.
The default value is 64.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the Walsh code length of a specific user-defined channel. This value is expressed in chips. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to
**User Defined**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.WALSH_CODE_LENGTH.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_walsh_code_length(self, selector_string, value):
r"""Sets the Walsh code length of a specific user-defined channel. This value is expressed in chips. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to
**User Defined**.
Use "channel<
<format type="monospace-italic">n</format>
>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to
configure or read this attribute.
The default value is 64.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the Walsh code length of a specific user-defined channel. This value is expressed in chips. This attribute is
used only when you set the :py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to
**User Defined**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.WALSH_CODE_LENGTH.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_walsh_code_number(self, selector_string):
r"""Gets the Walsh code number of a specific user-defined channel. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Use "channel<
<format type="monospace-italic">n</format>
>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to
configure or read this attribute.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the Walsh code number of a specific user-defined channel. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.WALSH_CODE_NUMBER.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_walsh_code_number(self, selector_string, value):
r"""Sets the Walsh code number of a specific user-defined channel. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Use "channel<
<format type="monospace-italic">n</format>
>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to
configure or read this attribute.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the Walsh code number of a specific user-defined channel. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.WALSH_CODE_NUMBER.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_branch(self, selector_string):
r"""Gets the branch on which a specific user-defined channel is mapped. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Use "channel<
<format type="monospace-italic">n</format>
>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to
configure or read this attribute.
The default value is **I**.
+--------------+-----------------------------------------------+
| Name (Value) | Description |
+==============+===============================================+
| I (0) | Specifies the in-phase branch. |
+--------------+-----------------------------------------------+
| Q (1) | Specifies the quadrature branch. |
+--------------+-----------------------------------------------+
| I and Q (2) | Specifies the in-phase and quadrature branch. |
+--------------+-----------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.Branch):
Specifies the branch on which a specific user-defined channel is mapped. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.BRANCH.value
)
attr_val = enums.Branch(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_branch(self, selector_string, value):
r"""Sets the branch on which a specific user-defined channel is mapped. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Use "channel<
<format type="monospace-italic">n</format>
>" as the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to
configure or read this attribute.
The default value is **I**.
+--------------+-----------------------------------------------+
| Name (Value) | Description |
+==============+===============================================+
| I (0) | Specifies the in-phase branch. |
+--------------+-----------------------------------------------+
| Q (1) | Specifies the quadrature branch. |
+--------------+-----------------------------------------------+
| I and Q (2) | Specifies the in-phase and quadrature branch. |
+--------------+-----------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.Branch, int):
Specifies the branch on which a specific user-defined channel is mapped. This attribute is used only when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.Branch else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.BRANCH.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_uplink_spreading_long_code_mask(self, selector_string):
r"""Gets the long code mask for reverse link spreading.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specifies the long code mask for reverse link spreading.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i64( # type: ignore
updated_selector_string,
attributes.AttributeID.UPLINK_SPREADING_LONG_CODE_MASK.value,
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_uplink_spreading_long_code_mask(self, selector_string, value):
r"""Sets the long code mask for reverse link spreading.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specifies the long code mask for reverse link spreading.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_i64( # type: ignore
updated_selector_string,
attributes.AttributeID.UPLINK_SPREADING_LONG_CODE_MASK.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_downlink_spreading_pn_offset(self, selector_string):
r"""Specified the PN offset in increments of 64 chips for forward link.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (int):
Specified the PN offset in increments of 64 chips for forward link.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.DOWNLINK_SPREADING_PN_OFFSET.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_downlink_spreading_pn_offset(self, selector_string, value):
r"""Specified the PN offset in increments of 64 chips for forward link.
You do not need to use a selector string to configure or read this attribute for the default signal instance.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ topic for
information about the string syntax for named signals.
The default value is 0.
Args:
selector_string (string):
Pass an empty string.
value (int):
Specified the PN offset in increments of 64 chips for forward link.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.DOWNLINK_SPREADING_PN_OFFSET.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_auto_level_initial_reference_level(self, selector_string):
r"""Gets the initial reference level that the `RFmxCDMA2k Auto Level <RFmxCDMA2kvi.chm/RFmxCDMA2k_Auto_Level.html>`_
method uses to estimate the peak power of the input signal. This value is expressed in dBm.
The default value is 30 dBm.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the initial reference level that the `RFmxCDMA2k Auto Level <RFmxCDMA2kvi.chm/RFmxCDMA2k_Auto_Level.html>`_
method uses to estimate the peak power of the input signal. This value is expressed in dBm.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string,
attributes.AttributeID.AUTO_LEVEL_INITIAL_REFERENCE_LEVEL.value,
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_auto_level_initial_reference_level(self, selector_string, value):
r"""Sets the initial reference level that the `RFmxCDMA2k Auto Level <RFmxCDMA2kvi.chm/RFmxCDMA2k_Auto_Level.html>`_
method uses to estimate the peak power of the input signal. This value is expressed in dBm.
The default value is 30 dBm.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the initial reference level that the `RFmxCDMA2k Auto Level <RFmxCDMA2kvi.chm/RFmxCDMA2k_Auto_Level.html>`_
method uses to estimate the peak power of the input signal. This value is expressed in dBm.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string,
attributes.AttributeID.AUTO_LEVEL_INITIAL_REFERENCE_LEVEL.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_limited_configuration_change(self, selector_string):
r"""Gets the set of attributes that are considered by RFmx in the locked signal configuration state.
If your test system performs the same measurement at different selected ports, multiple frequencies and/or
power levels repeatedly, enabling this attribute can help achieve faster measurements. When you set this attribute to a
value other than **Disabled**, the RFmx driver will use an optimized code path and skip some checks. Because RFmx skips
some checks when you use this attribute, you need to be aware of the limitations of this feature, which are listed in
the `Limitations of the Limited Configuration Change Property
<https://www.ni.com/docs/en-US/bundle/rfmx-wcdma-prop/page/rfmxwcdmaprop/limitations.html>`_ topic.
You can also use this attribute to lock a specific instrument configuration for a signal so that every time
that you initiate the signal, RFmx applies the RFmxInstr attributes from a locked configuration.
NI recommends you use this attribute in conjunction with named signal configurations. Create named signal
configurations for each measurement configuration in your test program and set this attribute to a value other than
**Disabled** for one or more of the named signal configurations. This allows RFmx to precompute the acquisition
settings for your measurement configurations and re-use the precomputed settings each time you initiate the
measurement. You do not need to use this attribute if you create named signals for all the measurement configurations
in your test program during test sequence initialization and do not change any RFInstr or personality attributes while
testing each device under test. RFmx automatically optimizes that use case.
Specify the named signal configuration you are setting this attribute in the selector string input. You do not
need to use a selector string to configure or read this attribute for the default signal instance. Refer to the
Selector String topic for information about the string syntax for named signals.
The default value is **Disabled**.
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+========================================+==========================================================================================================================+
| Disabled (0) | This is the normal mode of RFmx operation. All configuration changes in RFmxInstr attributes or in personality |
| | attributes will be applied during RFmx Commit. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| No Change (1) | Signal configuration is locked after the first Commit of the named signal configuration. Any configuration change |
| | thereafter either in RFmxInstr attributes or personality attributes will not be considered by subsequent RFmx Commits |
| | or Initiates of this signal. Use **No Change** if you have created named signal configurations for all measurement |
| | configurations but are setting some RFmxInstr attributes. Refer to the Limitations of the Limited Configuration Change |
| | Property topic for more details about the limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Frequency (2) | Signal configuration, other than center frequency and external attenuation, is locked after first Commit of the named |
| | signal configuration. Thereafter, only the Center Frequency and External Attenuation attribute value changes will be |
| | considered by subsequent driver Commits or Initiates of this signal. Refer to the Limitations of the Limited |
| | Configuration Change Property topic for more details about the limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Reference Level (3) | Signal configuration, other than the reference level, is locked after first Commit of the named signal configuration. |
| | Thereafter only the Reference Level attribute value change will be considered by subsequent driver Commits or Initiates |
| | of this signal. If you have configured this signal to use an IQ Power Edge Trigger, NI recommends that you set the IQ |
| | Power Edge Level Type to **Relative** so that the trigger level is automatically adjusted as you adjust the reference |
| | level. Refer to the Limitations of the Limited Configuration Change Property topic for more details about the |
| | limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Freq and Ref Level (4) | Signal configuration, other than center frequency, reference level, and external attenuation, is locked after first |
| | Commit of the named signal configuration. Thereafter only Center Frequency, Reference Level, and External Attenuation |
| | attribute value changes will be considered by subsequent driver Commits or Initiates of this signal. If you have |
| | configured this signal to use an IQ Power Edge Trigger, NI recommends you set the IQ Power Edge Level Type to |
| | **Relative** so that the trigger level is automatically adjusted as you adjust the reference level. Refer to the |
| | Limitations of the Limited Configuration Change Property topic for more details about the limitations of using this |
| | mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Selected Ports, Freq and Ref Level (5) | Signal configuration, other than selected ports, center frequency, reference level, external attenuation, and RFInstr |
| | configuration, is locked after first Commit or Initiate of the named signal configuration. Thereafter only Selected |
| | Ports, Center Frequency, Reference Level, and External Attenuation attribute value changes will be considered by |
| | subsequent driver Commits or Initiates of this signal. If you have configured this signal to use an IQ Power Edge |
| | Trigger, NI recommends you set the IQ Power Edge Level Type to **Relative** so that the trigger level is automatically |
| | adjusted as you adjust the reference level. Refer to the Limitations of the Limited Configuration Change Property topic |
| | for more details about the limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (enums.LimitedConfigurationChange):
Specifies the set of attributes that are considered by RFmx in the locked signal configuration state.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_i32( # type: ignore
updated_selector_string, attributes.AttributeID.LIMITED_CONFIGURATION_CHANGE.value
)
attr_val = enums.LimitedConfigurationChange(attr_val)
except (KeyError, ValueError):
raise errors.DriverTooNewError() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_limited_configuration_change(self, selector_string, value):
r"""Sets the set of attributes that are considered by RFmx in the locked signal configuration state.
If your test system performs the same measurement at different selected ports, multiple frequencies and/or
power levels repeatedly, enabling this attribute can help achieve faster measurements. When you set this attribute to a
value other than **Disabled**, the RFmx driver will use an optimized code path and skip some checks. Because RFmx skips
some checks when you use this attribute, you need to be aware of the limitations of this feature, which are listed in
the `Limitations of the Limited Configuration Change Property
<https://www.ni.com/docs/en-US/bundle/rfmx-wcdma-prop/page/rfmxwcdmaprop/limitations.html>`_ topic.
You can also use this attribute to lock a specific instrument configuration for a signal so that every time
that you initiate the signal, RFmx applies the RFmxInstr attributes from a locked configuration.
NI recommends you use this attribute in conjunction with named signal configurations. Create named signal
configurations for each measurement configuration in your test program and set this attribute to a value other than
**Disabled** for one or more of the named signal configurations. This allows RFmx to precompute the acquisition
settings for your measurement configurations and re-use the precomputed settings each time you initiate the
measurement. You do not need to use this attribute if you create named signals for all the measurement configurations
in your test program during test sequence initialization and do not change any RFInstr or personality attributes while
testing each device under test. RFmx automatically optimizes that use case.
Specify the named signal configuration you are setting this attribute in the selector string input. You do not
need to use a selector string to configure or read this attribute for the default signal instance. Refer to the
Selector String topic for information about the string syntax for named signals.
The default value is **Disabled**.
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (Value) | Description |
+========================================+==========================================================================================================================+
| Disabled (0) | This is the normal mode of RFmx operation. All configuration changes in RFmxInstr attributes or in personality |
| | attributes will be applied during RFmx Commit. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| No Change (1) | Signal configuration is locked after the first Commit of the named signal configuration. Any configuration change |
| | thereafter either in RFmxInstr attributes or personality attributes will not be considered by subsequent RFmx Commits |
| | or Initiates of this signal. Use **No Change** if you have created named signal configurations for all measurement |
| | configurations but are setting some RFmxInstr attributes. Refer to the Limitations of the Limited Configuration Change |
| | Property topic for more details about the limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Frequency (2) | Signal configuration, other than center frequency and external attenuation, is locked after first Commit of the named |
| | signal configuration. Thereafter, only the Center Frequency and External Attenuation attribute value changes will be |
| | considered by subsequent driver Commits or Initiates of this signal. Refer to the Limitations of the Limited |
| | Configuration Change Property topic for more details about the limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Reference Level (3) | Signal configuration, other than the reference level, is locked after first Commit of the named signal configuration. |
| | Thereafter only the Reference Level attribute value change will be considered by subsequent driver Commits or Initiates |
| | of this signal. If you have configured this signal to use an IQ Power Edge Trigger, NI recommends that you set the IQ |
| | Power Edge Level Type to **Relative** so that the trigger level is automatically adjusted as you adjust the reference |
| | level. Refer to the Limitations of the Limited Configuration Change Property topic for more details about the |
| | limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Freq and Ref Level (4) | Signal configuration, other than center frequency, reference level, and external attenuation, is locked after first |
| | Commit of the named signal configuration. Thereafter only Center Frequency, Reference Level, and External Attenuation |
| | attribute value changes will be considered by subsequent driver Commits or Initiates of this signal. If you have |
| | configured this signal to use an IQ Power Edge Trigger, NI recommends you set the IQ Power Edge Level Type to |
| | **Relative** so that the trigger level is automatically adjusted as you adjust the reference level. Refer to the |
| | Limitations of the Limited Configuration Change Property topic for more details about the limitations of using this |
| | mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
| Selected Ports, Freq and Ref Level (5) | Signal configuration, other than selected ports, center frequency, reference level, external attenuation, and RFInstr |
| | configuration, is locked after first Commit or Initiate of the named signal configuration. Thereafter only Selected |
| | Ports, Center Frequency, Reference Level, and External Attenuation attribute value changes will be considered by |
| | subsequent driver Commits or Initiates of this signal. If you have configured this signal to use an IQ Power Edge |
| | Trigger, NI recommends you set the IQ Power Edge Level Type to **Relative** so that the trigger level is automatically |
| | adjusted as you adjust the reference level. Refer to the Limitations of the Limited Configuration Change Property topic |
| | for more details about the limitations of using this mode. |
+----------------------------------------+--------------------------------------------------------------------------------------------------------------------------+
Args:
selector_string (string):
Pass an empty string.
value (enums.LimitedConfigurationChange, int):
Specifies the set of attributes that are considered by RFmx in the locked signal configuration state.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
value = value.value if type(value) is enums.LimitedConfigurationChange else value
error_code = self._interpreter.set_attribute_i32( # type: ignore
updated_selector_string,
attributes.AttributeID.LIMITED_CONFIGURATION_CHANGE.value,
value,
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_result_fetch_timeout(self, selector_string):
r"""Gets the time to wait before results are available in the RFmxCDMA2k Attribute. This value is expressed in
seconds.
Set this value to a time longer than expected for fetching the measurement. A value of -1 specifies that the
RFmxCDMA2k Attribute waits until the measurement is complete before fetching the measurement.
The default value is 10 seconds.
Args:
selector_string (string):
Pass an empty string.
Returns:
Tuple (attr_val, error_code):
attr_val (float):
Specifies the time to wait before results are available in the RFmxCDMA2k Attribute. This value is expressed in
seconds.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
attr_val, error_code = self._interpreter.get_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.RESULT_FETCH_TIMEOUT.value
)
finally:
self._session_function_lock.exit_read_lock()
return attr_val, error_code
@_raise_if_disposed
def set_result_fetch_timeout(self, selector_string, value):
r"""Sets the time to wait before results are available in the RFmxCDMA2k Attribute. This value is expressed in
seconds.
Set this value to a time longer than expected for fetching the measurement. A value of -1 specifies that the
RFmxCDMA2k Attribute waits until the measurement is complete before fetching the measurement.
The default value is 10 seconds.
Args:
selector_string (string):
Pass an empty string.
value (float):
Specifies the time to wait before results are available in the RFmxCDMA2k Attribute. This value is expressed in
seconds.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.set_attribute_f64( # type: ignore
updated_selector_string, attributes.AttributeID.RESULT_FETCH_TIMEOUT.value, value
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def abort_measurements(self, selector_string):
r"""Stops acquisition and measurements associated with the signal instance that you specify in the **Selector String**
parameter. The acquisition and measurements were previously initiated by the :py:meth:`initiate` method or measurement
read methods.
Calling this method is optional, unless you want to stop a measurement before it is complete. This method
executes even if there is an incoming error.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.abort_measurements( # type: ignore
updated_selector_string
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def auto_level(self, selector_string, measurement_interval):
r"""Examines the input signal to calculate the peak power level and sets it as the value of the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.REFERENCE_LEVEL` attribute. Use this method to calculate an approximate
setting for the reference level.
The RFmxCDMA2k Auto Level method does the following tasks:
#. Resets the mixer level, mixer level offset, and IF output power offset.
#. Sets the starting reference level to the maximum reference level supported by the device based on the current RF attenuation, mechanical attenuation, and preamplifier enabled settings.
#. Iterates to adjust the reference level based on the input signal peak power.
#. Uses immediate triggering and restores the trigger settings back to user setting after the execution.
You can also specify the starting reference level using the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.AUTO_LEVEL_INITIAL_REFERENCE_LEVEL` attribute.
When using NI 5663, 5665, or 5668R devices, NI recommends that you set an appropriate value for mechanical
attenuation before calling the RFmxCDMA2k Auto Level method. Setting an appropriate value for mechanical attenuation
reduces the number of times the attenuator settings are changed by this function; thus reducing wear and tear, and
maximizing the life time of the attenuator.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
measurement_interval (float):
This parameter specifies the acquisition length. This value is expressed in seconds. Use this value to compute the
number of samples to acquire from the signal analyzer.
Auto Level method does not use any trigger for acquisition. It ignores the user-configured trigger attributes.
NI recommends that you set a sufficiently high measurement interval to ensure that the acquired waveform is at least as
long as one period of the signal.
Returns:
Tuple (reference_level, error_code):
reference_level (float):
This parameter returns the estimated peak power level of the input signal. This value is expressed in dBm for RF
devices and V\ :sub:`pk-pk`\ for baseband devices. The default value of this parameter is hardware dependent.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
reference_level, error_code = self._interpreter.auto_level( # type: ignore
updated_selector_string, measurement_interval
)
finally:
self._session_function_lock.exit_read_lock()
return reference_level, error_code
@_raise_if_disposed
def check_measurement_status(self, selector_string):
r"""Checks the status of the measurement. Use this method to check for any errors that may occur during measurement or to
check whether the measurement is complete and results are available.
Args:
selector_string (string):
This parameter specifies a `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result
name. Examples:
""
"signal::sig1"
"result::r1"
"signal::sig1/result::r1"
You can use the :py:meth:`build_result_string` method to build the selector string.
Returns:
Tuple (done, error_code):
done (bool):
This parameter indicates whether the measurement is complete.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
done, error_code = self._interpreter.check_measurement_status( # type: ignore
updated_selector_string
)
finally:
self._session_function_lock.exit_read_lock()
return done, error_code
@_raise_if_disposed
def clear_all_named_results(self, selector_string):
r"""Clears all results for the signal that you specify in the **Selector String** parameter.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.clear_all_named_results( # type: ignore
updated_selector_string
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def clear_named_result(self, selector_string):
r"""Clears a result instance specified by the result name in the **Selector String** parameter.
Args:
selector_string (string):
This parameter specifies a `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result
name. Examples:
""
"signal::sig1"
"result::r1"
"signal::sig1/result::r1"
You can use the :py:meth:`build_result_string` method to build the selector string.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.clear_named_result( # type: ignore
updated_selector_string
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def commit(self, selector_string):
r"""Commits settings to the hardware. Calling this method is optional. RFmxCDMA2k commits settings to the hardware when you
call the :py:meth:`initiate` method.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.commit(updated_selector_string) # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def disable_trigger(self, selector_string):
r"""Configures the device to not wait for a trigger to mark a reference point within a record. This method defines the
signal triggering as immediate.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.disable_trigger(updated_selector_string) # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def initiate(self, selector_string, result_name):
r"""Initiates all enabled measurements. Call this method after configuring the signal and measurement.
This method asynchronously launches measurements in the background and immediately returns to the caller
program. You can fetch measurement results using the Fetch methods or result attributes in the attribute node. To get
the status of measurements, use the :py:meth:`wait_for_measurement_complete` method or
:py:meth:`check_measurement_status` method.
Args:
selector_string (string):
This parameter specifies a `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising the signal name and the result
name. The result name can either by specified through this input or the **Result Name** input. If you do not specify the result name in this input, either the
result name specified by the **Result Name** input or the default result instance is used.
Examples:
""
"signal::sig1"
"result::r1"
"signal::sig1/result::r1"
You can use the :py:meth:`build_result_string` method to build the selector string.
result_name (string):
This parameter specifies the name to be associated with measurement results. Provide a unique name, such as "r1" to
enable fetching of multiple measurement results and traces. This input accepts the result name with or without the
"result:" prefix. The default value is "" (empty string), which refers to the default result instance.
Examples:
""
"result::r1"
"r1"
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
_helper.validate_not_none(result_name, "result_name")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.initiate( # type: ignore
updated_selector_string, result_name
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def reset_to_default(self, selector_string):
r"""Resets a signal configuration to the default values.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.reset_to_default(updated_selector_string) # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def select_measurements(self, selector_string, measurements, enable_all_traces):
r"""Enables all the measurements that you specify in the **Measurements** parameter and disables all other measurements.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
measurements (enums.MeasurementTypes, int):
This parameter specifies the measurements to perform.
The default is an empty array.
+---------------+------------------------------------+
| Name (value) | Description |
+===============+====================================+
| ModAcc (0) | Enables the ModAcc measurement. |
+---------------+------------------------------------+
| ACP (1) | Enables the ACP measurement. |
+---------------+------------------------------------+
| CHP (2) | Enables the CHP measurement. |
+---------------+------------------------------------+
| OBW (3) | Enables the OBW measurement. |
+---------------+------------------------------------+
| SEM (4) | Enables the SEM measurement. |
+---------------+------------------------------------+
| QEVM (5) | Enables the QEVM measurement. |
+---------------+------------------------------------+
| CDA (6) | Enables the CDA measurement. |
+---------------+------------------------------------+
| SlotPhase (7) | Enables the SlotPhase measurement. |
+---------------+------------------------------------+
| SlotPower (8) | Enables the SlotPower measurement. |
+---------------+------------------------------------+
enable_all_traces (bool):
This parameter specifies whether to enable all traces for the selected measurements. The default value is **False**.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
measurements = (
measurements.value if type(measurements) is enums.MeasurementTypes else measurements
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.select_measurements( # type: ignore
updated_selector_string, measurements, int(enable_all_traces)
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def wait_for_measurement_complete(self, selector_string, timeout):
r"""Waits for the specified number of seconds for all the measurements to complete.
Args:
selector_string (string):
This parameter specifies a `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of result
name. Examples:
""
"signal::sig1"
"result::r1"
"signal::sig1/result::r1"
You can use the :py:meth:`build_result_string` method to build the selector string.
timeout (float):
This parameter specifies the timeout for fetching the specified measurement. This value is expressed in seconds. Set
this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the
method waits until the measurement is complete. The default value is 10.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.wait_for_measurement_complete( # type: ignore
updated_selector_string, timeout
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_band_class(self, selector_string, band_class):
r"""Configures the band class used for the measurement.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
band_class (int):
This parameter specifies the band in which the channel is located as defined in Section: 1.5, Table 1.5-1: Band Class
List, of the 3GPP2 C.S0057-F specification v1.0. The default value is **0**.
+--------------+-----------------------------------------------------+
| Name (value) | Description |
+==============+=====================================================+
| 0 (0) | Specifies the 800 MHz cellular band. |
+--------------+-----------------------------------------------------+
| 1 (1) | Specifies the 1.8 GHz to 2.0 GHz PCS band. |
+--------------+-----------------------------------------------------+
| 2 (2) | Specifies the 872 MHz to 960 MHz TACS band. |
+--------------+-----------------------------------------------------+
| 3 (3) | Specifies the 832 MHz to 925 MHZ JTACS band. |
+--------------+-----------------------------------------------------+
| 4 (4) | Specifies the 1.75 GHz to 1.87 GHz Korean PCS band. |
+--------------+-----------------------------------------------------+
| 5 (5) | Specifies the 450 MHz NMT band. |
+--------------+-----------------------------------------------------+
| 6 (6) | Specifies the 2 GHz IMT-2000 band. |
+--------------+-----------------------------------------------------+
| 7 (7) | Specifies the upper 700 MHz PARMR band. |
+--------------+-----------------------------------------------------+
| 8 (8) | Specifies the 1,800 MHz to 2 GHz band. |
+--------------+-----------------------------------------------------+
| 9 (9) | Specifies the 900 MHz band. |
+--------------+-----------------------------------------------------+
| 10 (10) | Specifies the secondary 1,800 MHz band. |
+--------------+-----------------------------------------------------+
| 11 (11) | Specifies the 400 MHz European PAMR band. |
+--------------+-----------------------------------------------------+
| 12 (12) | Specifies the 800 MHz PAMR band. |
+--------------+-----------------------------------------------------+
| 14 (14) | Specifies the US PCS 1.9 GHz band. |
+--------------+-----------------------------------------------------+
| 15 (15) | Specifies the AWS band. |
+--------------+-----------------------------------------------------+
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_band_class( # type: ignore
updated_selector_string, band_class
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_channel_configuration_mode(self, selector_string, channel_configuration_mode):
r"""Configures RFmx CDMA2k to detect the channels automatically or to use a specified channel configuration.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
channel_configuration_mode (enums.ChannelConfigurationMode, int):
This parameter specifies whether to detect the channels automatically or to use a specified channel configuration.
This parameter has no effect if radio configuration 1 or 2 (RC1 or RC2) is configured, as RC1 and RC2 always
use a single 64-ary Walsh-modulated channel.
+------------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (value) | Description |
+==================+==========================================================================================================================+
| Auto Detect (0) | Specifies that the system automatically detects the channels. |
+------------------+--------------------------------------------------------------------------------------------------------------------------+
| User Defined (1) | Specifies that the system uses a specific channel configuration. This mode increases measurement speed because no time |
| | is spent on channel detection. |
+------------------+--------------------------------------------------------------------------------------------------------------------------+
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
channel_configuration_mode = (
channel_configuration_mode.value
if type(channel_configuration_mode) is enums.ChannelConfigurationMode
else channel_configuration_mode
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_channel_configuration_mode( # type: ignore
updated_selector_string, channel_configuration_mode
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_digital_edge_trigger(
self, selector_string, digital_edge_source, digital_edge, trigger_delay, enable_trigger
):
r"""Configures the device to wait for a digital edge trigger and then marks a reference point within the record.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
digital_edge_source (string):
This parameter specifies the source terminal for the digital edge trigger. The default value of this parameter is
hardware dependent.
+-----------------------+-------------------------------------------------------+
| Name (value) | Description |
+=======================+=======================================================+
| PFI0 (PFI0) | The trigger is received on PFI 0. |
+-----------------------+-------------------------------------------------------+
| PFI1 (PFI1) | The trigger is received on PFI 1. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig0 (PXI_Trig0) | The trigger is received on PXI trigger line 0. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig1 (PXI_Trig1) | The trigger is received on PXI trigger line 1. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig2 (PXI_Trig2) | The trigger is received on PXI trigger line 2. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig3 (PXI_Trig3) | The trigger is received on PXI trigger line 3. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig4 (PXI_Trig4) | The trigger is received on PXI trigger line 4. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig5 (PXI_Trig5) | The trigger is received on PXI trigger line 5. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig6 (PXI_Trig6) | The trigger is received on PXI trigger line 6. |
+-----------------------+-------------------------------------------------------+
| PXI_Trig7 (PXI_Trig7) | The trigger is received on PXI trigger line 7. |
+-----------------------+-------------------------------------------------------+
| PXI_STAR (PXI_STAR) | The trigger is received on the PXI star trigger line. |
+-----------------------+-------------------------------------------------------+
digital_edge (enums.DigitalEdgeTriggerEdge, int):
This parameter specifies the trigger edge to detect. The default value is **Rising Edge**.
+------------------+--------------------------------------------------------+
| Name (value) | Description |
+==================+========================================================+
| Rising Edge (0) | The trigger asserts on the rising edge of the signal. |
+------------------+--------------------------------------------------------+
| Falling Edge (1) | The trigger asserts on the falling edge of the signal. |
+------------------+--------------------------------------------------------+
trigger_delay (float):
This parameter specifies the trigger delay time. This value is expressed in seconds. The default value is 0.
enable_trigger (bool):
This parameter specifies whether to enable the trigger. The default value is TRUE.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
_helper.validate_not_none(digital_edge_source, "digital_edge_source")
digital_edge = (
digital_edge.value
if type(digital_edge) is enums.DigitalEdgeTriggerEdge
else digital_edge
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_digital_edge_trigger( # type: ignore
updated_selector_string,
digital_edge_source,
digital_edge,
trigger_delay,
int(enable_trigger),
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_external_attenuation(self, selector_string, external_attenuation):
r"""Specifies any external attenuation to be considered by RFmx CDMA2k measurements, such as the attenuation of a switch or
cable connected to the signal analyzer RF IN connector.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
external_attenuation (float):
This parameter specifies the attenuation of a switch or cable connected to the signal analyzer RF IN connector. This
value is expressed in dB. The default value is 0 dB.
For more information about attenuation, refer to the RF Attenuation and Signal Levels topic for your device in
the *NI RF Vector Signal Analyzers Help*. The default value is 0.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_external_attenuation( # type: ignore
updated_selector_string, external_attenuation
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_frequency_channel_number(
self, selector_string, link_direction, band_class, channel_number
):
r"""Configures the expected carrier frequency of the RF signal to acquire according to the given channel number. The signal
analyzer tunes to this frequency.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
link_direction (enums.LinkDirection, int):
This parameter specifies the direction for which the frequency is calculated. Currently only **Uplink** is supported.
+--------------+------------------------------------------------------------------------------------------------+
| Name (value) | Description |
+==============+================================================================================================+
| Uplink (1) | The frequency is calculated in the reverse link direction, also known as the uplink direction. |
+--------------+------------------------------------------------------------------------------------------------+
band_class (int):
This parameter specifies the band in which the channel is located as defined in Section: 1.5, Table 1.5-1: Band Class
List, of the 3GPP2 C.S0057-F specification v1.0. The default value is **0**.
+--------------+-----------------------------------------------------+
| Name (value) | Description |
+==============+=====================================================+
| 0 (0) | Specifies the 800 MHz cellular band. |
+--------------+-----------------------------------------------------+
| 1 (1) | Specifies the 1.8 GHz to 2.0 GHz PCS band. |
+--------------+-----------------------------------------------------+
| 2 (2) | Specifies the 872 MHz to 960 MHz TACS band. |
+--------------+-----------------------------------------------------+
| 3 (3) | Specifies the 832 MHz to 925 MHZ JTACS band. |
+--------------+-----------------------------------------------------+
| 4 (4) | Specifies the 1.75 GHz to 1.87 GHz Korean PCS band. |
+--------------+-----------------------------------------------------+
| 5 (5) | Specifies the 450 MHz NMT band. |
+--------------+-----------------------------------------------------+
| 6 (6) | Specifies the 2 GHz IMT-2000 band. |
+--------------+-----------------------------------------------------+
| 7 (7) | Specifies the upper 700 MHz PARMR band. |
+--------------+-----------------------------------------------------+
| 8 (8) | Specifies the 1,800 MHz to 2 GHz band. |
+--------------+-----------------------------------------------------+
| 9 (9) | Specifies the 900 MHz band. |
+--------------+-----------------------------------------------------+
| 10 (10) | Specifies the secondary 1,800 MHz band. |
+--------------+-----------------------------------------------------+
| 11 (11) | Specifies the 400 MHz European PAMR band. |
+--------------+-----------------------------------------------------+
| 12 (12) | Specifies the 800 MHz PAMR band. |
+--------------+-----------------------------------------------------+
| 14 (14) | Specifies the US PCS 1.9 GHz band. |
+--------------+-----------------------------------------------------+
| 15 (15) | Specifies the AWS band. |
+--------------+-----------------------------------------------------+
channel_number (int):
This parameter specifies the channel number used to build the selector string.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
link_direction = (
link_direction.value
if type(link_direction) is enums.LinkDirection
else link_direction
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_frequency_channel_number( # type: ignore
updated_selector_string, link_direction, band_class, channel_number
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_frequency(self, selector_string, center_frequency):
r"""Configures the expected carrier frequency of the RF signal to acquire. The signal analyzer tunes to this frequency.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
center_frequency (float):
This parameter specifies the carrier frequency of the RF signal to acquire. The signal analyzer tunes to this
frequency. This value is expressed in Hz. The default value of this parameter is hardware dependent.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_frequency( # type: ignore
updated_selector_string, center_frequency
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_iq_power_edge_trigger(
self,
selector_string,
iq_power_edge_source,
iq_power_edge_slope,
iq_power_edge_level,
trigger_delay,
minimum_quiet_time_mode,
minimum_quiet_time,
iq_power_edge_level_type,
enable_trigger,
):
r"""Configures the device to wait for the complex power of the I/Q data to cross the specified threshold to mark a
reference point within the record.
To trigger on burst signals, specify a minimum quiet time. The minimum quiet time ensures that the trigger does
not occur in the middle of the burst signal. The quiet time must be set to a value smaller than the time between bursts
but large enough to ignore power changes within a burst.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
iq_power_edge_source (string):
This parameter specifies the channel from which the device monitors the trigger. The default value of this parameter is
hardware dependent.
iq_power_edge_slope (enums.IQPowerEdgeTriggerSlope, int):
This parameter specifies whether the device asserts the trigger when the signal power is rising or when it is falling.
The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. The
default value is **Rising Slope**.
+-------------------+-------------------------------------------------------+
| Name (value) | Description |
+===================+=======================================================+
| Rising Slope (0) | The trigger asserts when the signal power is rising. |
+-------------------+-------------------------------------------------------+
| Falling Slope (1) | The trigger asserts when the signal power is falling. |
+-------------------+-------------------------------------------------------+
iq_power_edge_level (float):
This parameter specifies the power level at which the device triggers. This value is expressed in dB when you set the
**IQ Power Edge Level Type** parameter to **Relative**; and is expressed in dBm when you set the **IQ Power Edge Level
Type** parameter to **Absolute**. The device asserts the trigger when the signal exceeds the level specified by the
value of this parameter, taking into consideration the specified slope. The default of this attribute is hardware
dependent.
trigger_delay (float):
This parameter specifies whether the trigger is used. The default value is TRUE.
minimum_quiet_time_mode (enums.TriggerMinimumQuietTimeMode, int):
This parameter specifies the trigger delay time. This value is expressed in seconds. The default value is 0.
minimum_quiet_time (float):
This parameter specifies whether the measurement computes the minimum quiet time used for triggering. The default value
is **Auto**.
+--------------+----------------------------------------------------------------------------------------------------+
| Name (value) | Description |
+==============+====================================================================================================+
| Manual (0) | The minimum quiet time for triggering is the value you specify using the Minimum Quiet Time input. |
+--------------+----------------------------------------------------------------------------------------------------+
| Auto (1) | The measurement computes the minimum quiet time used for triggering. |
+--------------+----------------------------------------------------------------------------------------------------+
iq_power_edge_level_type (enums.IQPowerEdgeTriggerLevelType, int):
This parameter specifies the time duration for which the signal must be quiet before the signal analyzer arms the I/Q
power edge trigger. This value is expressed in seconds.
If you set the **IQ Power Edge Slope** parameter to **Rising Slope**, the signal is quiet while it is below
the trigger level. If you set the **IQ Power Edge Slope** parameter to **Falling Slope**, the signal is quiet when it
is above the trigger level. The default value of this parameter is hardware dependent.
enable_trigger (bool):
This parameter specifies the reference for the** IQ Power Edge Level** parameter. The **IQ Power Edge Level Type**
parameter is used only when you set the Trigger Type attribute to **IQ Power Edge**.
+--------------+----------------------------------------------------------------------------------------------+
| Name (value) | Description |
+==============+==============================================================================================+
| Relative (0) | The IQ Power Edge Level attribute is relative to the value of the reference level attribute. |
+--------------+----------------------------------------------------------------------------------------------+
| Absolute (1) | The IQ Power Edge Level attribute specifies the absolute power. |
+--------------+----------------------------------------------------------------------------------------------+
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
_helper.validate_not_none(iq_power_edge_source, "iq_power_edge_source")
iq_power_edge_slope = (
iq_power_edge_slope.value
if type(iq_power_edge_slope) is enums.IQPowerEdgeTriggerSlope
else iq_power_edge_slope
)
minimum_quiet_time_mode = (
minimum_quiet_time_mode.value
if type(minimum_quiet_time_mode) is enums.TriggerMinimumQuietTimeMode
else minimum_quiet_time_mode
)
iq_power_edge_level_type = (
iq_power_edge_level_type.value
if type(iq_power_edge_level_type) is enums.IQPowerEdgeTriggerLevelType
else iq_power_edge_level_type
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_iq_power_edge_trigger( # type: ignore
updated_selector_string,
iq_power_edge_source,
iq_power_edge_slope,
iq_power_edge_level,
trigger_delay,
minimum_quiet_time_mode,
minimum_quiet_time,
iq_power_edge_level_type,
int(enable_trigger),
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_radio_configuration(self, selector_string, radio_configuration):
r"""Configures the radio configuration of the CDMA2k signal.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
radio_configuration (enums.RadioConfiguration, int):
This parameter specifies the radio configuration of the CDMA2k signal to be analyzed. The default value is **RC3**.
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| Name (value) | Description |
+==============+==========================================================================================================================+
| RC1 (0) | For Uplink, Radio configuration 1 includes 64-ary orthogonal modulation, reverse fundamental channel (R-FCH) and |
| | reverse supplemental code channels (R-SCCHs). For Downlink, Radio Configuration 1 includes binary phase-shift keying |
| | (BPSK), forward fundamental channels (F-FCHs) and forward supplemental channels (F-SCHs). |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC2 (1) | For Uplink, Radio configuration 2 includes 64-ary orthogonal modulation, R-FCH and R-SCCHs. For Downlink, Radio |
| | Configuration 2 includes BPSKs, F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC3 (2) | For Uplink, Radio configuration 3 includes binary phase shift keying (BPSK), R-FCH and reverse supplemental channels |
| | (R-SCHs). For Downlink, Radio Configuration 3 includes quadrature phase-shift keying (QPSK), F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC4 (3) | For Uplink, Radio configuration 4 includes BPSK, R-FCH and R-SCHs. For Downlink, Radio Configuration 4 includes QPSK, |
| | F-FCHs and F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
| RC5 (4) | For Uplink, Radio configuration 5 is not supported. For Downlink, Radio Configuration 5 includes QPSK, F-FCHs and |
| | F-SCHs. |
+--------------+--------------------------------------------------------------------------------------------------------------------------+
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
radio_configuration = (
radio_configuration.value
if type(radio_configuration) is enums.RadioConfiguration
else radio_configuration
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_radio_configuration( # type: ignore
updated_selector_string, radio_configuration
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_uplink_spreading(self, selector_string, uplink_spreading_long_code_mask):
r"""Configures the scrambling code used for the uplink transmission.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
uplink_spreading_long_code_mask (int):
This parameter specifies the long code mask for uplink spreading. This number is a 42-bit binary number, represented as
a 64-bit integer. The default value is 0.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_uplink_spreading( # type: ignore
updated_selector_string, uplink_spreading_long_code_mask
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_user_defined_channel_array(
self, selector_string, walsh_code_length, walsh_code_number, branch
):
r"""Configures all user-defined channels when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Use equal-sized arrays for **Walsh Code Length**, **Walsh Code Number**, and **Branch**.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
walsh_code_length (int):
This parameter specifies an array of the Walsh code length of the CDMA2k signal. The default value is 64.
walsh_code_number (int):
This parameter specifies an array of the Walsh code number of the CDMA2k signal. The default value is 0.
branch (enums.Branch, int):
This parameter specifies an array of the branch on which a specific user-defined channel is mapped. The default value
is **I**.
+--------------+-----------------------------------------------+
| Name (value) | Description |
+==============+===============================================+
| I (0) | Specifies the in-phase branch. |
+--------------+-----------------------------------------------+
| Q (1) | Specifies the quadrature branch. |
+--------------+-----------------------------------------------+
| I and Q (2) | Specifies the in-phase and quadrature branch. |
+--------------+-----------------------------------------------+
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
branch = (
[v.value for v in branch]
if (isinstance(branch, list) and all(isinstance(v, enums.Branch) for v in branch))
else branch
)
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_user_defined_channel_array( # type: ignore
updated_selector_string, walsh_code_length, walsh_code_number, branch
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_user_defined_channel(
self, selector_string, walsh_code_length, walsh_code_number, branch
):
r"""Configures an individual user-defined channel when the channel configuration mode is set to **User Defined**.
Use "channel<n>" as the selector string to configure this method.
A channel is defined by the Walsh code length and number and the quadrature branch on which it is mapped.
Args:
selector_string (string):
This parameter specifies a `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ comprising of channel
number. Examples:
"channel0"
"signal::sig1/channel0"
You can use the :py:meth:`build_channel_string` method to build the selector string.
walsh_code_length (int):
This parameter specifies the Walsh code length of a specific user-defined channel. The default value is 64.
walsh_code_number (int):
This parameter specifies the Walsh code number of a specific user-defined channel. The default value is 0.
branch (enums.Branch, int):
This parameter specifies the branch on which a specific user-defined channel is mapped. The default value is **I**.
+--------------+-----------------------------------------------+
| Name (value) | Description |
+==============+===============================================+
| I (0) | Specifies the in-phase branch. |
+--------------+-----------------------------------------------+
| Q (1) | Specifies the quadrature branch. |
+--------------+-----------------------------------------------+
| I and Q (2) | Specifies the in-phase and quadrature branch. |
+--------------+-----------------------------------------------+
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
branch = branch.value if type(branch) is enums.Branch else branch
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_user_defined_channel( # type: ignore
updated_selector_string, walsh_code_length, walsh_code_number, branch
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_rf(
self, selector_string, center_frequency, reference_level, external_attenuation
):
r"""Configures the RF attributes of the signal specified by the **Selector String** parameter.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
center_frequency (float):
This parameter specifies the carrier frequency of the RF signal to acquire. This value is expressed in Hz. The signal
analyzer tunes to this frequency. The default value of this parameter is hardware dependent. Refer to the 3GPP2
standard C.S0057-E v1.0 for more information about bands.
reference_level (float):
This parameter specifies the reference level, which represents the maximum expected power of an RF input signal. This
value is expressed in dBm for RF devices and V\ :sub:`pk-pk`\ for baseband devices. The default value of this parameter
is hardware dependent.
external_attenuation (float):
This parameter specifies the attenuation of a switch or cable connected to the RF IN connector of the signal analyzer.
This value is expressed in dB.
For more information about attenuation, refer to the RF Attenuation and Signal Levels topic for your device in
the *NI RF Vector Signal Analyzers Help*. The default value is 0.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_rf( # type: ignore
updated_selector_string, center_frequency, reference_level, external_attenuation
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_reference_level(self, selector_string, reference_level):
r"""Configures the reference level. The reference level represents the maximum expected power of an input RF signal.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
reference_level (float):
This parameter specifies the reference level, which represents the maximum expected power of an RF input signal. This
value is expressed in dBm for RF devices and V\ :sub:`pk-pk`\ for baseband devices. The default value of this parameter
is hardware dependent.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_reference_level( # type: ignore
updated_selector_string, reference_level
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_software_edge_trigger(self, selector_string, trigger_delay, enable_trigger):
r"""Configures the device to wait for a software trigger and then marks a reference point within the record.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
trigger_delay (float):
This parameter specifies the trigger delay time. This value is expressed in seconds. The default value is 0.
enable_trigger (bool):
This parameter specifies whether to enable the trigger. The default value is TRUE.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_software_edge_trigger( # type: ignore
updated_selector_string, trigger_delay, int(enable_trigger)
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@staticmethod
def build_result_string(result_name):
r"""Creates selector string for use with configuration or fetch.
Args:
result_name (string):
Specifies the result name for building the selector string.
This input accepts the result name with or without the "result::" prefix.
Example: "", "result::r1", "r1".
Returns:
string:
Contains the selector string created by this method.
"""
_helper.validate_not_none(result_name, "result_name")
return _helper.build_result_string(result_name)
@staticmethod
def build_offset_string(selector_string, offset_number):
r"""Creates the offset string to use as the selector string with the SEM and ACP offset configuration for fetch attributes
and methods.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_
topic for information about the string syntax for named signals.
Args:
selector_string (string):
Specifies the result name for building the selector string.
offset_number (int):
This parameter specifies the offset number used to build the selector string.
Returns:
string:
Contains the selector string created by this method.
"""
_helper.validate_not_none(selector_string, "selector_string")
return _helper.build_offset_string(selector_string, offset_number) # type: ignore
@staticmethod
def build_channel_string(selector_string, channel_number):
r"""Creates a selector string to use with channel configuration.
Refer to the `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_
topic for information about the string syntax for named signals.
Args:
selector_string (string):
Specifies the result name for building the selector string.
channel_number (int):
This parameter specifies the channel number used to build the selector string.
Returns:
string:
Contains the selector string created by this method.
"""
_helper.validate_not_none(selector_string, "selector_string")
return _helper.build_channel_string(selector_string, channel_number) # type: ignore
@_raise_if_disposed
def clone_signal_configuration(self, new_signal_name):
r"""Creates a new instance of a signal by copying all the properties from an existing signal instance.
Args:
new_signal_name (string):
This parameter specifies the name of the new signal. This parameter accepts the signal name with or without the \"signal::\" prefix.
Example:
\"signal::NewSigName\"
\"NewSigName\"
Returns:
Tuple (cloned_signal, error_code):
cloned_signal (Cdma2k):
Contains a new CDMA2k signal instance.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(new_signal_name, "new_signal_name")
updated_new_signal_name = _helper.validate_and_remove_signal_qualifier(
new_signal_name, self
)
cloned_signal, error_code = self._interpreter.clone_signal_configuration( # type: ignore
self.signal_configuration_name, updated_new_signal_name
)
finally:
self._session_function_lock.exit_read_lock()
return cloned_signal, error_code
@_raise_if_disposed
def send_software_edge_trigger(self):
r"""Sends a trigger to the device when you use the RFmxCDMA2k Configure Trigger function to choose a software version of a trigger and the device is waiting for the trigger to be sent. You can also use this function to override a hardware trigger.
This function returns an error in the following situations:
- You configure an invalid trigger.
- You have not previously called the initiate function.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
error_code = self._interpreter.send_software_edge_trigger() # type: ignore
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def get_all_named_result_names(self, selector_string):
r"""Returns all the named result names of the signal that you specify in the Selector String parameter.
Args:
selector_string (string):
Pass an empty string. The signal name that is passed when creating the signal configuration is used.
Returns:
Tuple (result_names, default_result_exists, error_code):
result_names (string):
Returns an array of result names.
default_result_exists (bool):
Indicates whether the default result exists.
error_code (int):
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
result_names, default_result_exists, error_code = (
self._interpreter.get_all_named_result_names(updated_selector_string) # type: ignore
)
finally:
self._session_function_lock.exit_read_lock()
return result_names, default_result_exists, error_code
@_raise_if_disposed
def analyze_iq_1_waveform(self, selector_string, result_name, x0, dx, iq, reset):
r"""Performs the enabled measurements on the I/Q complex waveform that you specify in the **IQ** parameter. Call this
method after you configure the signal and measurement attributes. You can fetch measurement results using the Fetch
methods or result attributes in the attribute node.
Use this method only if the :py:attr:`~nirfmxinstr.attribute.AttributeID.RECOMMENDED_ACQUISITION_TYPE` attribute value
is either **IQ** or **IQ or Spectral**.
When using the Analysis-Only mode in RFmxCDMA2k, the RFmx driver ignores the RFmx hardware settings such as reference level
and attenuation. The only RF hardware settings that are not ignored are the center frequency and trigger type, since it is
needed for spectral measurement traces as well as some measurements such as ModAcc, ACP, and SEM.
.. note::
Query the Recommended Acquisition Type attribute from the RFmxInstr Attribute after calling the :py:meth:`commit`
method.
Args:
selector_string (string):
This parameter specifies the result name. The result name can either be specified through this input
or the **Result Name** parameter. If you do
not specify the result name in this parameter, either the result name specified by the **Result Name** parameter or
the default result instance is used.
Example:
""
"result::r1"
You can use the :py:meth:`build_result_string` method to build the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_.
result_name (string):
This parameter specifies the name to be associated with measurement results. Provide a unique name, such as "r1" to
enable fetching of multiple measurement results and traces. This input accepts the result name with or without the
"result::" prefix. The default value is "" (empty string), which refers to the default result instance.
Example:
""
"result::r1"
"r1"
x0 (float):
This parameter specifies the start time of the input **y** array. This value is expressed in seconds.
dx (float):
This parameter specifies the time interval between the samples in the input **y** array. This value is expressed in
seconds. The reciprocal of **dx** indicates the I/Q rate of the input signal.
iq (numpy.complex64):
This parameter specifies an array of complex-valued time domain data. The real and imaginary parts of this complex data
array correspond to the in-phase (I) and quadrature-phase (Q) data, respectively.
reset (bool):
This parameter resets measurement averaging. If you enable averaging, set this parameter to TRUE for the first record
and FALSE for the subsequent records.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
_helper.validate_not_none(result_name, "result_name")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.analyze_iq_1_waveform( # type: ignore
updated_selector_string, result_name, x0, dx, iq, reset
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def analyze_spectrum_1_waveform(self, selector_string, result_name, x0, dx, spectrum, reset):
r"""Performs the enabled measurements on the spectrum that you specify in the **Spectrum** parameter. Call this method
after you configure the signal and measurement attributes. You can fetch measurement results using the Fetch methods or
result attributes in the attribute node.
Use this method only if the :py:attr:`~nirfmxinstr.attribute.AttributeID.RECOMMENDED_ACQUISITION_TYPE` attribute value
is either **Spectral** or **IQ or Spectral**.
.. note::
Query the Recommended Acquisition Type attribute from the RFmxInstr Attribute after calling the :py:meth:`commit`
method.
Args:
selector_string (string):
This parameter specifies the result name. The result name can either be specified through this input
or the **Result Name** parameter. If you do
not specify the result name in this parameter, either the result name specified by the **Result Name** parameter or
the default result instance is used.
Example:
""
"result::r1"
You can use the :py:meth:`build_result_string` method to build the `Selector String
<https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_.
result_name (string):
This parameter specifies the name to be associated with measurement results. Provide a unique name, such as "r1" to
enable fetching of multiple measurement results and traces. This input accepts the result name with or without the
"result::" prefix. The default value is "" (empty string), which refers to the default result instance.
Example:
""
"result::r1"
"r1"
x0 (float):
This parameter specifies the start frequency of the spectrum. This value is expressed in Hz.
dx (float):
This parameter specifies the frequency interval between data points in the spectrum.
spectrum (numpy.float32):
This parameter specifies the data for a spectrum waveform.
reset (bool):
This parameter resets measurement averaging. If you enable averaging, set this parameter to TRUE for the first record
and FALSE for the subsequent records.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
_helper.validate_not_none(result_name, "result_name")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.analyze_spectrum_1_waveform( # type: ignore
updated_selector_string, result_name, x0, dx, spectrum, reset
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
@_raise_if_disposed
def configure_number_of_channels(self, selector_string, number_of_channels):
r"""Configures the number of channels for the user-defined channel configuration when you set the
:py:attr:`~nirfmxcdma2k.attributes.AttributeID.CHANNEL_CONFIGURATION_MODE` attribute to **User Defined**.
Args:
selector_string (string):
Pass an empty string.
The signal name that is passed when creating the signal configuration is used.
number_of_channels (int):
This parameter specifies the number of user-defined channels. The default value is 0.
Returns:
int:
Returns the status code of this method. The status code either indicates success or describes a warning condition.
"""
try:
self._session_function_lock.enter_read_lock()
_helper.validate_not_none(selector_string, "selector_string")
updated_selector_string = _helper.validate_and_update_selector_string(
selector_string, self
)
error_code = self._interpreter.configure_number_of_channels( # type: ignore
updated_selector_string, number_of_channels
)
finally:
self._session_function_lock.exit_read_lock()
return error_code
[docs]
class Cdma2k(_Cdma2kBase):
"""Defines a root class which is used to identify and control Cdma2k signal configuration."""
def __init__(self, session, signal_name="", cloning=False):
"""Initializes a Cdma2k signal configuration."""
super(Cdma2k, self).__init__(
session=session,
signal_name=signal_name,
cloning=cloning,
) # type: ignore
def __enter__(self):
"""Enters the context of the Cdma2k signal configuration."""
return self
def __exit__(self, exc_type, exc_value, traceback):
"""Exits the context of the Cdma2k signal configuration."""
self.dispose() # type: ignore